Application of Deep Reinforcement Learning to Event-Triggered Control for Networked Artificial Pancreas Systems
Ikemoto, Junya, Maruyama, Satoshi, Hashimoto, Kazumune
This paper proposes a deep reinforcement learning (DRL)-based event-triggered controller design for networked artificial pancreas (AP) systems. Although existing DRL-based AP controllers typically assume periodic control updates, networked control systems (NCSs) require a reduction in communication frequency to achieve energy-efficient operation, which is directly tied to control updates. However, jointly learning both insulin dosing and update timing significantly increases the complexity of the learning problem. To alleviate this complexity, we develop a practical DRL-based controller design that avoids explicitly learning update timing by introducing a rule-based criterion defined by changes in blood glucose. As a result, decision-making occurs at irregular intervals, and the problem is naturally formulated as a semi-Markov decision process (SMDP), for which we extend a standard DRL algorithm. Numerical experiments demonstrate that the proposed method improves communication efficiency while maintaining control performance.
Type 1 Diabetes Management using GLIMMER: Glucose Level Indicator Model with Modified Error Rate
Khamesian, Saman, Arefeen, Asiful, Grando, Adela, Thompson, Bithika, Ghasemzadeh, Hassan
Managing Type 1 Diabetes (T1D) demands constant vigilance as individuals strive to regulate their blood glucose levels to avert the dangers of dysglycemia (hyperglycemia or hypoglycemia). Despite the advent of sophisticated technologies such as automated insulin delivery (AID) systems, achieving optimal glycemic control remains a formidable task. AID systems integrate continuous subcutaneous insulin infusion (CSII) and continuous glucose monitors (CGM) data, offering promise in reducing variability and increasing glucose time-in-range. However, these systems often fail to prevent dysglycemia, partly due to limitations in prediction algorithms that lack the precision to avert abnormal glucose events. This gap highlights the need for proactive behavioral adjustments. We address this need with GLIMMER, Glucose Level Indicator Model with Modified Error Rate, a machine learning approach for forecasting blood glucose levels. GLIMMER categorizes glucose values into normal and abnormal ranges and devises a novel custom loss function to prioritize accuracy in dysglycemic events where patient safety is critical. To evaluate the potential of GLIMMER for T1D management, we both use a publicly available dataset and collect new data involving 25 patients with T1D. In predicting next-hour glucose values, GLIMMER achieved a root mean square error (RMSE) of 23.97 (+/-3.77) and a mean absolute error (MAE) of 15.83 (+/-2.09) mg/dL. These results reflect a 23% improvement in RMSE and a 31% improvement in MAE compared to the best-reported error rates.
Stacked LSTM Based Deep Recurrent Neural Network with Kalman Smoothing for Blood Glucose Prediction
Rabby, Md Fazle, Tu, Yazhou, Hossen, Md Imran, Le, Insup, Maida, Anthony S, Hei, Xiali
Blood glucose (BG) management is crucial for type-1 diabetes patients resulting in the necessity of reliable artificial pancreas or insulin infusion systems. In recent years, deep learning techniques have been utilized for a more accurate BG level prediction system. However, continuous glucose monitoring (CGM) readings are susceptible to sensor errors. As a result, inaccurate CGM readings would affect BG prediction and make it unreliable, even if the most optimal machine learning model is used. In this work, we propose a novel approach to predicting blood glucose level with a stacked Long short-term memory (LSTM) based deep recurrent neural network (RNN) model considering sensor fault. We use the Kalman smoothing technique for the correction of the inaccurate CGM readings due to sensor error. For the OhioT1DM dataset, containing eight weeks' data from six different patients, we achieve an average RMSE of 6.45 and 17.24 mg/dl for 30 minutes and 60 minutes of prediction horizon (PH), respectively. To the best of our knowledge, this is the leading average prediction accuracy for the ohioT1DM dataset. Different physiological information, e.g., Kalman smoothed CGM data, carbohydrates from the meal, bolus insulin, and cumulative step counts in a fixed time interval, are crafted to represent meaningful features used as input to the model. The goal of our approach is to lower the difference between the predicted CGM values and the fingerstick blood glucose readings - the ground truth. Our results indicate that the proposed approach is feasible for more reliable BG forecasting that might improve the performance of the artificial pancreas and insulin infusion system for T1D diabetes management.